This is our single point of contact for security reports about all products listed below. Please start the subject line with SECURITY, so the message is handled with priority.
You may also contact us by post or phone, whichever you prefer. A person reads every report — there is no form, ticket system or chatbot in between.
Phone and company details: Impressum
During the support period we fix vulnerabilities and publish the fixes free of charge. The support period applies per product, or per release where stated.
| Product | Type | How to find your version | Security support until |
|---|---|---|---|
| GPIBEE adapter | USB & Ethernet to GPIB adapter (hardware with firmware) | Web interface, Home page; or *IDN? to the adapter's internal SCPI device |
15 November 2031 |
| GPIBee488 V0.9.10 | IEEE 488.2 library for Windows (gpib-32.dll) and GPIBee-488 interactive control |
Windows Explorer: Properties → Details of a DLL, or version.txt in the release |
29 November 2031 (5 years after release on 29 November 2026) |
For the GPIBEE adapter, every new firmware version (a new major or minor version number, for example V1.7 to V1.8) starts a new support period of 5 years from the date of its first release, for all units of the hardware revisions it supports. Later builds of the same version, including security updates, do not change this date. The date in the table is 5 years after the first release of the newest version (firmware V1.7.2611152105, released 15 November 2026) and moves forward with each new version. Security updates are free of charge throughout.
For GPIBee488, each release has its own support period of 5 years from its release date. A security fix may come as a newer release that replaces an older one; installing it keeps you within the support period. Future GPIBee488 releases are added to this table with their own end date.
We welcome reports from customers, researchers and anyone else who finds a security weakness in our products. This policy describes what you can expect from us and what we ask of you.
gpib-32.dll and the interactive control.Not in scope: the gpibee.com website itself (please still tell us if you find a problem there), third-party VISA libraries, and the instruments connected to the GPIB bus.
Please write in English or German. If you need to send sensitive details encrypted, say so in a first short message and we will agree a method with you.
Where the EU Cyber Resilience Act requires it, we notify actively exploited vulnerabilities and severe incidents to the competent CSIRT (in Germany the BSI) and to ENISA through the single reporting platform. When a vulnerability lies in a third-party component we use, we also inform the maintainer of that component.
If you act in good faith and follow this policy, we will not take legal action against you for your research, and we will work with you to understand and fix the problem.
Every security fix is announced here with the affected versions, the fixed version, its severity and what you should do.
| ID | Date | Product | Summary | Fixed in |
|---|---|---|---|---|
| No security advisories have been published so far. | ||||
To be told when an update is released, subscribe to the firmware notifications on the firmware page or follow the news.
Security updates are free of charge. None of our products updates itself or downloads anything from the internet, so there is no automatic update setting to turn off: you decide when to install an update. Every security update stays available for download for at least 10 years, or for the rest of the support period if that is longer.
Download the firmware from the firmware page and install it over USB (drag and drop onto the GPIBEE drive) or from the web interface (firmware V1.7 or newer). Settings are kept. Firmware images are encrypted and integrity-checked; the adapter only accepts images built by us. The bootloader is stored separately and cannot be overwritten by an interrupted update.
Close all programs that use the library, then replace every installed file (the DLL of each bitness and the interactive control) with the files of the new release, in the same places as before. Do not mix files from different releases. The adapter assignment in the registry is kept. Afterwards, the file properties show the new version.
Our products connect PCs to GPIB test and measurement instruments. They are intended for laboratories, development, production test and service, operated by qualified staff, on a local network or USB connection that only trusted people and devices can reach. They are not intended for safety functions.
192.168.3.2).| Situation | Risk | What to do |
|---|---|---|
| Adapter on a network that untrusted people or devices can reach, or reachable from the internet | Others can send commands to your instruments, read or change measurement data, change adapter settings or start a firmware update. | Use an isolated lab network or VLAN, or USB. Never forward the adapter's ports to the internet. Reach remote labs through a VPN. |
| Web and REST interface open on the network | Anyone who can reach the adapter can change its configuration. | Keep the adapter on a trusted network. Where your firmware version offers a web interface password, set one. |
| Discovery protocols on a shared network | SSDP and mDNS make the adapter visible to everyone on the network. | Switch off SSDP, mDNS and the ++ network protocol if you do not need them. |
| GPIBee488 automatic search on a shared network | A device pretending to be a GPIBee could be picked as GPIB0; the numbering can change. | Assign adapters by address (GPIBee488 manual, section 5.2). The search is then not used. |
| GPIBee488 DLLs in a folder that other users can write to | A manipulated gpib-32.dll would run with the rights of everyone who starts the program. | Install into folders only administrators can change. Do not run measurement programs from shared or download folders. |
| Software or firmware from an unknown source | Files with the same name could be manipulated. | Download only from gpibee.com or an authorised distributor. For GPIBee488 check the file properties: company “Gossner Electronics & Embedded Systems GmbH” and the version you expect. |
| GPIBee488 trace log left switched on | The log records addresses, host names, file names and program paths, and may be readable by other users. | Use tracing only for troubleshooting, delete the log afterwards and remove GPIBEE_TRACE. |
| Commands that act on real equipment | Wrong or unauthorised commands can switch outputs on, change ranges or damage connected equipment. | Limit who can run measurement programs; protect safety-relevant setups with hardware interlocks. |
| Outdated firmware or software | Known weaknesses stay open. | Watch this page and install updates. |
Configuring a default gateway, forwarding ports, connecting the adapter to a shared or public network, enabling network services, using modified or mixed files, and the GPIBee488 variables GPIBEE488_DISCOVER and GPIBEE_TRACE all change who can reach the product or what is recorded. Use only unchanged files of one release and the settings described in the manuals.
HKCU\Software\GPIBee\gpibee488 (and HKLM\SOFTWARE\GPIBee\gpibee488 if set machine-wide), delete any trace logs and remove the variables GPIBEE_TRACE and GPIBEE488_DISCOVER. Details are in section 13.9 of the GPIBee488 manual.| Product | Components |
|---|---|
| GPIBee488 | Own code of Gossner Electronics & Embedded Systems GmbH; MinGW-w64 runtime and GCC runtime library (built in at compile time); Windows system libraries (used from Windows, not shipped). No other third-party libraries. |
| GPIBEE firmware | A software bill of materials is available on request from support@gpibee.com. |
| Product | Declaration |
|---|---|
| GPIBEE adapter | EU declaration of conformity, hardware revision 2.0 (PDF) |
| Manufacturer | Gossner Electronics & Embedded Systems GmbH, [shown with JavaScript], [shown with JavaScript], Germany |
| Trademark | GPIBEE |
| support@gpibee.com | |
| Web | www.gpibee.com |
| Company details | Impressum |
Last updated: 29 November 2026